Chapter:

Quantity-of-Waste-Water

A certain district of a city has a projected population of 50,000 residing over an area of 40 hectares. Find design discharge for sewer line, for following data :

  • Rate of water supply = 200 lpcd
  • Average impermeability coefficient for entire area =0.3 
  • Time of concentration = 50 minutes 

The sewer line is to be designed for a flow equivalent to wet wear flow (WWF) plus twice dry wear flow (DWF).Use British ministry of health formula. Assume that `70%` of water supply reaches in sewer as wastewater.(Ans: `0.648 m^3/s`) 

Solution:

Given,

Population = 50,000

Area = 40 ha.

Peak factor = 2

Rate of water supply = 200 lpcd

Avg. impermeability factor = 0.3

Time of concentration = 50 min

Now,

The discharge of DWF is,

`Q_(DWF)=(2**0.7**50000**200)/(1000**86400)`

`=0.1620 m^2/s`

Again,

Intensity of rainfall is given by,

`i=1020/(t+20)=1020/70=14.5714` mm/hr

Now, the storm water flow rate is,

`Q_(WWF)=(CiA)/360`

`=(0.3**14.5714**40)/360`

`=0.4857 m^3/s`

Thus, the combined design discharge is,

`Q=Q_(DWF)+Q_(WWF)`

`=0.1620 + 0.4857`

`=0.6477 m^3/s`

Show More

Similar Question

This Chapter Quantity-of-Waste-Water consists of the following topics

How is the quantity of storm water estimated.

A certain district of a city has a projected population of 50,000 residing over an area of 40 hectares. Find design discharge for sewer line, for following data :

  • Rate of water supply = 200 lpcd
  • Average impermeability coefficient for entire area =0.3 
  • Time of concentration = 50 minutes 

The sewer line is to be designed for a flow equivalent to wet wear flow (WWF) plus twice dry wear flow (DWF).Use British ministry of health formula. Assume that `70%` of water supply reaches in sewer as wastewater.(Ans: `0.648 m^3/s`) 

Assuming the surface on which rain falls in a thickly build up residential district as follows : 

  • `40 %` area consists of roofs and pavements (`C_1 = 0.80`) 
  • `60 %` of area consists of lawns and gardens (`C_2 = 0.2`)  

Calculate the coefficient of runoff. If the area of the district is 2 hectares and the maximum intensity of rainfall is taken as 50 mm/hr, what is the runoff of the district?  (Ans: `0.44, 0.122` `m^3`/sec)  

A certain district of a city has a projected population of 50

000 residing over an area of 40 hectares. Find the design discharge for the sewer line

for the following data : Rate of water supply = 200 lpcd Average impermeability coefficient for the entire area =0.3 Time of concentration = 50 minutes The sewer line is to be designed for a flow equivalent to the wet weather flow (WWF) plus twice the dry weather flow (DWF).Use British ministry of health formula. Assume that `70%` of water supply reaches in the sewer as wastewater.(Ans: `0.648 m^3/s`) 

Quantity of Waste Water

Sanitary-Engineering